Fabric water vapour permeability testing apparatus is for assessment of the water vapour permeability ability of fabrics by moisture permeable cup moisture absorption method. The instrument is used to determine moisture (steam) permeability of various types of fabrics (including moisture-permeable coated fabrics) as well as cotton and space cotton for non-woven clothing. Moisture permeability can reflect the perspiration and steam permeability of clothing, one of the important indicators to identify the comfort and hygiene of clothing.
アプリケーション
The instrument is used to determine moisture (steam) permeability of various types of fabrics (including moisture-permeable coated fabrics) as well as cotton and space cotton for non-woven clothing.標準
GB/T 12704.1-2009 織物-Test Methods for Water Vapor Transmission of Materials-Part 1: Moisture absorption method.
GB/T 12704.2-2009 織物-Test Methods for Water Vapor Transmission of Materials-Part 2: Evaporation method.
ASTM E96-00 Standard Test Methods for Water Vapor Transmission of Materials
BS7209:1990 Specification for water vapour permeable apparel fabrics.
Model B/C Fabrics Water Vapour Permeability Testing Apparatus:
Consist of the main box with the refrigeration system and instrument control cabinet.
Wind speed adjustable.
The United States standard square moisture permeable cups for thick samples and circular moisture permeable cups for thin samples, four cups for each type;
3 GB standard moisture permeable cups.
PID self-tuning temperature / humidity control device.
Digital timer.
Start timer button / stop timer button.
特徴
Model A Fabrics Water Vapour Permeability Testing Apparatus:
The instrument has a PID self-tuning temperature / humidity control device (with a high precision PT100 sensor). Temperature and humidity can be set on the instrument panel as needed.
Digital timer.
Double insulated glass door and test chamber with pure stainless steel inner tank.
技術パラメータ
プロジェクト | パラメータ |
Temperature range | 5℃~40℃±0.5℃ higher than the ambient temperature (without refrigeration ) |
しつどはんい | Indoor relative humidity~90%RH |
Temperature accuracy | Indicating value±2% |
Test time | 0~99.99h |
Heating power | 700W |
humidification amount | ≥250mL/h |
電源装置 | AC220V,50Hz |
Model A Fabrics Water Vapour Permeability Testing Apparatusプロジェクト | パラメータ |
Temperature range | 20℃~40℃±0.5℃ |
しつどはんい | (50±2)%RH~(90±2)%RH |
Airflow velocity | 0.02m/s~0.3m/s |
Test time | 0~99.99h |
Heating power | 600W |
Humidification amount | ≥250mL/h |
電源装置 | AC220V,50Hz |
Note: ASTM E96-00 standard specifies test temperature at 21℃~32℃±1℃; Recommended test temperature and humidity conditions: 1、General test: temperature (23±1)℃, relative humidity (50±2)%RH 2、High temperature and high humidity test: temperature (38±1)℃, relative humidity (90±2)%RH |
|