STD-TE 69 ENHANCED LOAD SCANNER - Qinsun
専門検査機器メーカー
全国問い合わせホットライン:+86 021-64208466
製品

STD-TE 69 ENHANCED LOAD SCANNER

DescriptionWith the STD-TE 69 Load Scanner geometry, the samples are indexed and the load applied b

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

コンテンツ

説明

With the STD-TE 69 Load Scanner geometry, the samples are indexed and the load applied by three independently controlled, but synchronised motion, actuators. Two elongated test specimens, preferably bars or rods, are used. The orientation of the test specimens and their relative sliding motion during testing is arranged in such a way that the contact spot moves along a contact path on each specimen; each spot along this path on one specimen will only make contact with one spot on the other specimen, and vice-verse. The contact spot is the area over which the contact load is distributed.

Standard Load Scanner Applications

A single pass experiment resembles the test procedure often used in scratch testing of coated specimens. For coatings evaluation, it is normal to have one specimen coated and select the material from the practical application, for the counter specimen.

Reciprocating sliding tests, with stroke-wise load variation, can be used to produce conditions ranging from mild wear to scuffing, at different positions on a single pair of specimens.

Technical Specifications

Contact Geometry:Crossed Cylinder on Cylinder

Crossed Flat on Flat

Pin on Plate

Indenter on Plate
Test Modes:Load scanner with ramped load

Pin on plate with constant load

Scratch test mode with ramped load

Repeat scratch test with unloaded reverse stroke
Maximum Load:2000 N
Tooling Clamps Unheated:3.2 mm diameter and 12 mm diameter
Tooling Clamps Heated:3.2 mm diameter and 12 mm diameter
Cylinder Length:175 mm
Wear Scar Length – Load Scanner:100 mm
Wear Scar Length – Pin on Plate:75 mm
Maximum Stage Travel:75 mm (each)
Maximum Repetition Rate:0.3 Hz
Lubricant Bath Temperature:Ambient to 250°C
Upper Rod Specimen Temperature:Ambient to 600°C (dry tests only)
Lower Rod Specimen Temperature:Ambient to 600°C (dry tests only)
Load and Traverse Actuators (Qty: 3):Servo-controlled Ball Screw

Dynamic Force: 700 N

Static Force: 700 N

Maximum Traverse Speed: 150 mm/s
Load Arm Ratio:5:1
Actuator Motors:400 W










Automatically Controlled ParametersTraverse Speed

Bath Temperature (lubricated tests)

Upper Specimen Temperature (dry tests)

Lower Specimen Temperature (dry tests)

テスト期間


Mechanically Adjusted ParametersStarting Load

Rate of Loading


Recorded ParametersTraverse Speed

ふか

Stroke Displacement

Friction Force

Bath Temperature (lubricated tests)

Upper Specimen Temperature (dry tests)

Lower Specimen Temperature (dry tests)

Number of Cycles

テスト期間

Friction Coefficient