Features and Benefits 1. Durable2. Dust circulation system3. High safetyThe inne
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
1. Durable | 2. Dust circulation system | 3. High safety |
The inner wall of the workroom made of SUS 304 can resist the sand erosion of long-term high wind speed. | The O-type vertical dust cycle is also conducive to the uniform distribution of dust. | Equipped with electromagnetic lock to prevent sand leakage caused by misoperation, and rubber strip to reinforce the sealing. |
4. Intelligent programmable controller | 5. Easy to power the test piece | 6. Meet the IPX5 IPX6 standard |
Programmable control of all parameters, the test is fully automated. | The workroom is equipped with a single phase 16A internal power interface to power. | The talc powder diameter is 50um, and the mesh filter diameter is 75um. |
Model | DI-800 | DI-1000 | DI-1500 | DI-2000 |
Internal Dimension (mm) | 800*1000*1000 | 1000*1000*1000 | 1000*1500*1000 | 1000*2000*1000 |
Overall Dimension (mm) | 1040*1450*1960 | 1330*1450*1960 | 1330*1950*1990 | 1330*2450*1990 |
Useful Volume (L) | 800 | 1000 | 1500 | 2000 |
おんどはんい | Ambient ~ +50℃ | |||
Humidity Range | < 30% RH | |||
Normal Wire Diameter | 50um | |||
Nominal Width of a Gap Between wires | 75um | |||
Fight Time | 0 ~ 99H59M | |||
Blowing Time | 0 ~ 99H59M | |||
Specimen Power Outlet | Dust-proof socket 16A | |||
Controller | Programmable color LCD touch screen controller, Ethernet connection | |||
Safety Device | Over-temperature Protection; Over-current Protection; Earth Leakage Protection; Phase Sequence Protection | |||
Exterior Material | A3 Steel Plate with protective coating | |||
Interior Material | SUS304 stainless steel | |||
Standard Configuration | Sample shelf, dust wiper, talcum powder(5kgs) | |||
Power | AC380V 50Hz |