BFE Tester - Qinsun
専門検査機器メーカー
全国問い合わせホットライン:+86 021-64208466

BFE Tester

Bacterial Filtration Efficiency TesterSurgical Mask Tester Bacterial Filtration Efficiency (BFE) Det

電子メール:info@standard-groups.com

コンテンツ

Bacterial Filtration Efficiency Tester

Surgical Mask Tester Bacterial Filtration Efficiency (BFE) Detector is mainly applicable to the measurement and verification departments, scientific research institutes, medical mask manufacturers and relevant testing departments for the performance of mask bacterial filtration efficiency.

Bacterial Filtration Efficiency Tester is applied to test the filtration efficiency of mask, can be used in metering calibration department, scientific research institution, mask manufacturer and other related departments.

Bacterial & Viral Filtration Efficiency Tester
 
BFE Tester 標準:

YY 0469-2004外科マスク技術要求

BS EN 14683-2014医療用マスク-要求と試験方法

ASTM F2100-2019 Standard Specification for Performance of Materials Used in Medical Face Masks   
         
ASTM F 2101黄色ブドウ球菌バイオエアロゾルを用いた医療用マスク材料の細菌濾過効率(BFE)評価のための標準的な試験方法
 
Mask Bacterial Filtration Efficiency Tester Feature:

1.Switching type glass door in front of the machine, easy to observe by the operator.

2.蠕動ポンプは負圧箱に取り付けられ、A& ;B 2ウェイ6段アンダーソンサンプリングヘッド。

3.The flow speed of peristaltic pump can be set.BFE tester good atomization effect.

4.Bacterial Filtration Efficiency Tester Of Mask: Negative pressure testing system, which can protect operator’s safety.

5.The spray flow of bacterial liquid inside the special microbial aerosol generator can be set.

6.10.4 "industrial high brightness color touch screen display.Embedded high speed industrial microcomputer control.


Parameter:
 
Main Parameter Parameter range
vacuum pumpOil-free rotary vane vacuum pump, maximum flow up to 57LPM, equipped with muffler, stable airflow
Aerosol generator flow controlThe flow control of aerosol generator adopts mass flow control and the control is accurate
Channel I sampling flowAnderson sampling flow of 28.3 L/min, resolution: 0.1 L/min
sampling flowAnderson sampling flow of 28.3 L/min, resolution: 0.1 L/min
samplingEquipped with mass flow controller
Pneumatic pressure0-5KPa
Spray flowmeter pressure0-300KPa
aerosol chamber negative pressure0-120KPa
動作温度0-50
Cabinet negative pressure0-120Pa
Cabinet negative pressureData can be downloaded via usb flash drive
Data storage capacityData can be downloaded via usb flash drive
mass flow controller0-20L/min,resolution:0.1 L/min
Peristaltic pump flow(0.01~3.0)mL/min

免責事項: 上記のコンテンツは,業界内部者のみの参照およびコミュニケーションのためであり,その正確性または完全性を保証しません.関連法規および本ウェブサイトの規制により,関連品を購入するユニットまたは個人は,有効な資格および資格条件を取得する必要があります.


オンラインメッセージ

連絡先情報

会社電話

+86-21-6420 0566

営業時間

月曜日から金曜日

携帯電話:

13816217984

メール:

info@qinsun-lab.com

QRコード