**Scope of Application**Determines the liquid loss performance of nonwoven fabrics. Place a standard
電子メール:info@standard-groups.com
**Scope of Application**
Determines the liquid loss performance of nonwoven fabrics. Place a standard absorbent medium beneath the test specimen, position the combined sample on an inclined platform, and measure the liquid penetration through the nonwoven fabric into the absorbent medium when a specific volume of artificial urine flows downward. Calculate the liquid loss performance by weighing the absorbent medium before and after testing.
**Compliance Standards**
Edana 152.0-99; ISO 9073-11
**Technical Specifications**
1. Test bench features two black reference lines:
- Low line: Located 3±0.2 mm above the bench end (absorbent medium position)
- High line: Approximately 25 mm below specimen top (aligns with drainage tube center)
2. Bench inclination: 25°
3. Clamp assembly:
- Adjustable device for fixing specimens symmetrically at (140±0.2) mm from reference line
4. Central positioning mechanism
5. Absorbent pad support frame at specimen lower edge
6. Glass tube specifications:
- Inner diameter: 5 mm
7. Ring-shaped base plate
8. Drip feeding system:
- Delivers (25±0.5) g test liquid continuously through glass tube in (4±0.1) seconds