Protective clothing heat conduction tester - Qinsun
専門検査機器メーカー
全国問い合わせホットライン:+86 021-64208466

Protective clothing heat conduction tester

Overview1.1 Applicable for testing thermal protection performance of single-layer or multi-layer mat

電子メール:info@standard-groups.com

コンテンツ

概要

1.1 Applicable for testing thermal protection performance of single-layer or multi-layer materials used in protective clothing exposed to convective and radiant heat hazards. Not suitable for non-flammable materials or those prone to melting/dripping at high temperatures.
1.2 Design principle:
  a. Horizontal placement of flame-retardant samples under combined convective/radiant heat sources
  b. Exposure time recorded when transmitted heat equals second-degree burn threshold
  c. Direct contact simulation (0mm gap) vs spaced contact (6.5mm gap)
  d. Thermal protection value (TPP) calculation: Intersection of heat flux-time curve with Stoll curve
  e. Stoll curve: Standard curve relating burn time to energy exposure – values above curve indicate risk of second-degree burns

Compliance Standards

GB 8965.1-2009 Appendix A, GA 10-2014 Appendix A, NFPA 1971-2017, ISO 12749, GB/T 38302-2019

Product Advantages

1. Computerized control system with LabVIEW software integration
  a. User-friendly interface with automated calculations
  b. Real-time data acquisition (20 samples/sec) and Stoll curve intersection detection
  c. Intelligent temperature compensation algorithm
2. Automated thermal shield system:
  a. ≤0.5s response time for heat shield retraction
  b. Water-cooled shielding mechanism
3. Precision ignition system:
  a. High-voltage spark generator with safety interlock
  b. 38mm diameter gas burner with adjustable air/fuel mixture
4. TPP automatic calculation:
  a. Integration of exposure time and total heat flux
  b. Digital display of calculated TPP value

Technical Specifications

仕様詳細
4.1 Heat sources4.1.1 Radiant: 9×T-150 quartz lamps (10–50 kW/cm² @ 127mm)
4.1.2 Convective: Twin gas burners (45° angle, 10–50 kW/cm² each)
4.1.3 Total heat flux: 83±2 kW/cm²
4.2 SensorsCopper calorimeter probe (Φ25mm) with ±0.1℃ resolution
Stoll curve intersection detection system
4.3 Data acquisition20 Hz sampling rate prior to 250℃
Automatic TPP calculation via software integration
4.4 Safety featuresHigh-voltage interlock system
Water-cooled shield mechanism
Emergency shutdown protocol
4.5 DimensionsMain chamber: 800×500×550mm
Instrument footprint: 1200×800×1000mm
4.6 Power requirementsAC 220V±10% 50Hz, 3kW maximum