Product introduction The device is designed based on a variety of battery short-circuit test standa
電子メール:info@standard-groups.com
Product introduction
The device is designed based on a variety of battery short-circuit test standards.
According to the standard requirements, the short-circuit device must meet the
internal resistance range of 80 soil 20m, so as to obtain the maximum short-circuit
current required by the test. In addition, the circuit design of the short-circuit device
must also be able to withstand the impact of large current, so we choose industrial
grade DC electromagnetic contactors and all copper terminals and internal copper
plates to guide the flow, wide and thick copper plates effectively improve the heat
dissipation effect, make the high-current short-circuit device safer, effectively reduce
the loss of test equipment, and ensure the accuracy of the test data.
Meet the standard
GB/T31485-2015 "Safety requirements and test methods for power batteries for
electric vehicles"
GB/T31241-2022 "Safety requirements for Lithium-ion batteries and battery packs
for portable electronic products"
UN38.3 United Nations Manual of Tests and Standards for the Transport of
Dangerous Goods
IEC62133 "Safety requirements for batteries (groups) composed of cells and for
use in portable equipment"
UL1642:2012 "Lithium Battery Standard"
Technical parameter
Inner box size :400x400x400mm(width x depth x height)
Size :760x690x1720mm(width x Depth x height)
Temperature range :RT+10-150℃C
Temperature display accuracy :0.1°C
Temperature stability: 1.0*C
Temperature uniformity: 2 "C
Heating time :(5±2) "C/min
Inner box material :SUS304 stainless steel plate, thickness 1.2mm;
Outer box material: 1.5mm thick cold rolled steel plate paint treatment;
Observation window: 250x250mm tempered glass, with stainless steel mesh;
Lighting device: The machine is equipped with a light, which is convenient to
observe the state of the tested sample;
Door: single door open left, side of the door is equipped with explosion-proof
chain;
Test hole: There are 2 test holes with a diameter of 50mm on the right side of
the equipment, which is convenient to put the temperature, voltage, current and
other collection lines:
Insulation material: high efficiency compressed glass wool
Heat preservation device: no fuse switch, over temperature protection switch, fuse
Safety device: equipment equipped with overtemperature alarm;
Control formation: reach the set time to cut off the heating power supply;
Air supply circulation system: convection air supply circulation system
Control mode: touch screen control
Temperature collection range :RT-1000°C;
Temperature acquisition channel :1 channel;
Temperature acquisition accuracy: 1.5°C;
Voltage acquisition model :0-100V;
Voltage acquisition channel :1 channel;
Voltage accuracy: Earth 0.5%FS;
Current collection range :0-1000A;
Current acquisition channel :1 channel;
Current accuracy: soil 0.5%FS;
Acquisition frequency :10HZ
Internal resistance of device loop :80 20mΩ;
Port pressure port: The opening size is 200x200mm, located at the back of the box.
When the sample explodes, the pressure relief port will pop open and remove the
pressure;
Device movement: there are four universal casters at the bottom of the device,
which can move freely;
Equipment weight :170Kg;
Power supply :AC220V;
Power :3KW.