IntroductionIt adopts the internationally popular method of heat flow meter to detect thermal c

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

コンテンツ

紹介

It adopts the internationally popular method of heat flow meter to detect thermal conductivity and thermal resistance, and realizes fully automatic detection with computer and generates experimental report. The instrument adopts to add stable hot surface temperature on one side of the specimen, the heat is transferred to the cold surface through the specimen, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Adopting imported sensors and computer technology, the instrument is characterized by good measurement accuracy, high reliability and good repeatability good characteristics. Especially suitable for low thermal conductivity measurement (accurate to 0.1mw). It can be used for testing plastics, rubber, thermal insulation materials, aerogel panels, vacuum glass, etc. It is widely used in colleges and universities, scientific research institutes, quality inspection, factories and mines.

Reference standard:

ASTME1530.ASTM C518-04 Test method for determining steady-state heat flux and heat transfer characteristics by the thermofluid meter method

Model: FTech- ASTM E 1530

Technical Parameter

1. The range of thermal conductivity: 0.0001 ~ 1W / mk, can be measured accurately to 0.1mw / mk.

0.001~300W/mk. computer automatically switch the range.

2. Measurement accuracy: 1%.

3. Sample size: 50 × 50 ~ 300 × 300 (mm) (standard configuration), the thickness is not greater than 50mm.

600 × 600. 800 × 600 (mm) and other special sizes can be customized.

4. Can test solid material, powder material.

5. Measuring time 15~20 min.

6. Hot surface temperature and control: room temperature ~ 99.9 ℃ (standard configuration), room temperature ~ 299.9 ℃, room temperature ~ 499.9 ℃. Plate heater, bi-directional SCR control, temperature control accuracy 0.1℃.

7. Cold surface temperature and control: 0 ~ 99.9 ℃ (standard configuration), -10 ~ 99.9 ℃, according to user    requirements to determine the lower temperature. Cold surface temperature and control The cold surface is water-cooled to ensure the stability of the cold surface temperature (precision thermostatic water tank, temperature adjustable), temperature control accuracy of 0.1 ℃.

8. The specimen using computerized precise pressure clamping, pressure range 0 ~ 1000N, resolution 0.1N.

9. Automatic measurement of specimen thickness, 0~50mm, resolution 1um.

10. Imported original heat flow meter, stable and reliable performance.

11. The whole process adopts computerized automatic testing and printing and save experimental data.

Packing list

1. One host computer;

2. A set of analysis software (Chinese and English version);

3. HX-1005 precision low-temperature constant temperature water tank a (temperature control accuracy 0.01 ℃);

5. Standard sample*1pcs;

Dimension:

1. Host: Standard floor model: (L×W×H) 550×450×1500mm, net weight: 100Kg.

2. Precision low-temperature constant temperature water tank: (L×W×H) 300×350×530mm, net weight: 35Kg.