Detailed Product DescriptionApplicable Standard:SH/T0059;ASTM D5800Temperature Control Mode:Dig
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
Applicable Standard: | SH/T0059;ASTM D5800 | Temperature Control Mode: | Digital Display PID Temperature Control |
---|---|---|---|
Temperature Control Range: | Room Temperature ~ 250 ± 0.1 ℃, Precision 0.01 ℃ | Heating Mode: | Metal Bath Heating |
Pressure Regulation: | High Precision Needle Valve | Suction Method: | Vacuum Pump |
Differential Pressure Meter: | Imported Precision Slant Tube Differential Pressure Meter | ||
Highlight: | Noack Method Evaporation Loss Analyzer Lubricating Oil Evaporation Loss Tester ASTM D5800 Evaporation Loss Analyzer |
This instrument is designed and manufactured as per procedure A of SH/T 0059 and procedure A of ASTM D5800 Standard Method for Evaporation Loss of Lubricating Oils by the Noack Method.
It is used to determine the evaporation loss of lubricating oils (particularly engine oils). The evaporation measured is reported as percent total loss.
1. The instrument should be placed on a fixed and flat workbench. Cross-ventilation should be avoided as far as possible in the environment.
2. No naked fire is allowed around the instrument during operation because of inflammable materials.
3. The instrument should be placed in the dry and ventilated environment.
4. The power supply should be single-phase and three-wire. The instrument must be grounded well.
Technical Features
This instrument is mainly composed of a heating bath and a filtering unit. It has below features:
1. Metal-blocked heating bath. Safe and environmental.
2. Wood-metal is used to provide good heating performance.
3. Specialized vacuum filtering system is equipped.
4. A digital timer is equipped for recording the test time.
5. International brand needle valve and precise pressure regulation system makes the flow correct.
6. Colored touch LCD operation. Easy to use.
Applicable standard | SH/T0059 |
Temperature control mode | digital display PID temperature control |
Temperature control range | room temperature ~ 250 ± 0.1 ℃, precision 0.01 ℃ |
Heating mode | metal bath heating |
Pressure regulation | high precision needle valve |
Suction method | vacuum pump |
Differential pressure meter | imported precision slant tube differential pressure meter |
免責事項: 上記のコンテンツは,業界内部者のみの参照およびコミュニケーションのためであり,その正確性または完全性を保証しません.関連法規および本ウェブサイトの規制により,関連品を購入するユニットまたは個人は,有効な資格および資格条件を取得する必要があります.
会社電話
+86-21-6420 0566
営業時間
月曜日から金曜日
携帯電話:
13816217984
メール:
info@qinsun-lab.com