Application Scope of the AC/DC Current - Carrying Temperature - Rise and Voltage - Drop Test System
電子メール:info@standard-groups.com
Application Scope of the AC/DC Current - Carrying Temperature - Rise and Voltage - Drop Test System for Automotive Wires:
1. Record the temperature change of conductors in connectors under a certain current. 2. Record the magnitude of the current passing through conductors in connectors at the set conductor temperature. 3. Record the changes in voltage drop. 4. Have a cyclic testing function.
Test Standards:Test requirements such as JASO D609: 2001, QC/T29106, QC/T 1067.1, QC/T417.1, TICW15, etc.
Main Parameters:
1) Input voltage: AC380V ±10%, 50Hz 2) Types of load power supplies: DC: switching power supply; AC: AC constant - current source 3) Operating current: AC: 1000A, open - circuit voltage: maximum 10V; DC: 10 - 1000A, open - circuit voltage: maximum output voltage 10V 4) Current output mode: Set by computer 5) Ammeter accuracy: ±1% + 3 digits 6) DC voltage drop: One range is 0.01mV - 199.99mV, and another is 0.1mV - 1999.9mV 7) Timing range: 0 - 9999.99H/M/S. When the timing is up, the current can be automatically cut off. 8) Eight - channel test temperature meters are standard - equipped, which can display and record in real - time the temperature values of T1C, T2c, T3C, T1s and the ambient temperature (Thermocouple type: T - type 30AWG thermocouple) 9) Temperature control and monitoring of the constant - temperature chamber
免責事項: 上記のコンテンツは,業界内部者のみの参照およびコミュニケーションのためであり,その正確性または完全性を保証しません.関連法規および本ウェブサイトの規制により,関連品を購入するユニットまたは個人は,有効な資格および資格条件を取得する必要があります.
会社電話
+86-21-6420 0566
営業時間
月曜日から金曜日
携帯電話:
13816217984
メール:
info@qinsun-lab.com