専門検査機器メーカー
全国問い合わせホットライン:+86 021-64208466

IEC60695 Needle Flame Tester

The device use needle flame to simulate small flame effect resulted from equipment incorrect operati

電子メール:info@standard-groups.com

コンテンツ
The device use needle flame to simulate small flame effect resulted from equipment incorrect operation so as to evaluate fire hazard.
Expose the specimen to fire in a certain time. The temperature of the copper block is measured by K-type mineral insulated metal sheathed thermocouples (level 1) conforming to IEC 60584-2
The calibration device is capable of automatically measuring the time interval between 100 ° C and 700 ° C and calculating the mean value of the three measurements. The calibration device is also equipped with a digital-analog temperature output that can be used to measure the external time interval.

image.png

紹介


Technical Parameters


ItemsParameters
SpecimenSynthetic materials
Test standardsDIN EN 60695-11-5
SensorTemperature
Power supply230 VAC / 15 VA
Dimension500 x 400 x 300 mm (W x D x H)
Weight15g