専門検査機器メーカー
全国問い合わせホットライン:+86 021-64208466

Double Plate Thermal Conductivity Apparatus

Double plate thermal conductivity tester integrated water bath thermostat equipment, all measurement

電子メール:info@standard-groups.com

コンテンツ

Double plate thermal conductivity tester integrated water bath thermostat equipment, all measurement and control are used computer control. Mainly testing plastic, rubber, glass, fiberboard, benzene board, extruded board, foam concrete, hollow glass, wood, all kinds of insulation materials such as homogeneous plate material, and can measure the pellets, bulk materials, soft materials and other Thermal conductivity of matter. The instrument can be widely used in heat and insulation materials production enterprises, the relevant quality inspection departments and units, institutions of higher learning and research institutes and other scientific research units.
 
image.png
Standards
GB/T 10294-2008  Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials
GB/T 3399-1982   Test method for thermal conductivity of plastics - Heat - resistant plate method
GB/T 10801.1-2002  Thermal insulation polystyrene foam
GB/T 10801.2-2002   Extruded polystyrene foam
GB/T 3139-2005        Test method for thermal conductivity of fiber reinforced plastics
GB/T 17794-2008      Flexible foam rubber and plastic insulation products

Features
Chassis is nice. Test box shell uses spray method. It has strong mechanical strength, anti-corrosion
The device is small and the unique casters are designed to increase the flexibility of the thermometer movement.
High safety performance. It not only adopts the use of circuit and refrigeration cycle independent design, but also can ensure that the electrical part of the collected data from the impact of water, and improve stability.
Good performance of temperature stability and unique protection board design, can form a one-dimensional protection, so that it has no loss of temperature.
Online double standard company unique technology which can calibrate the temperature, calibration system error, is accurate, fast and convenient.
 
Technical Parameters

ItemsParameters
Specimen standard size300mm × 300mm × H (5 ~ 40) mm
Specimen flatness0.1mm
Thermal conductivity measurement display range (0.001 ~ 2.000) W / (m • K)
Thermal conductivity measurement accuracy± 3%
Thermal conductivity measurement Repeatability± 1%
Temperature resolution0.01 ℃
Temperature control accuracy0.05 ℃


Technical Parameters

Different types of thermal conductivity tester temperature measurement rangeModelCold plate temperature control interface ℃Hot plate temperature control range ℃
IMDRY3001-IRoom temperature - 95 ℃Room temperature - 100 ℃
IMDRY3001-Ⅱ-℃ -5 ℃ - 95 ℃15 ℃ - 95 ℃
IMDRY3001-Ⅲ-10 ℃ - 95 ℃10 ℃ - 95 ℃
IMDRY3001-IV-15 ℃ - 95 ℃5 ℃ - 95 ℃
IMDRY3001-V-20 ° C - 95 ° C0 ° C - 95 ° C
IMDRY3001-Ⅵ    -30 ℃ -95 ℃-10 ℃ -95 ℃
IMDRY3001-VII-40 ℃- 95 ℃ -20 ℃ - 95 ℃
Power supplyAC 220V ± 10%, 2.5KW
Specimen thicknessStandard 25mm, range (5 ~ 40) mm
Specimen thermal resistance requirementsthe thermal resistance of the specimen should not be less than 0.1 (m2 • K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 • K) / W, the accuracy does not necessarily meet the requirements.
Clamping forceNo more than 2.5kPa

免責事項: 上記のコンテンツは,業界内部者のみの参照およびコミュニケーションのためであり,その正確性または完全性を保証しません.関連法規および本ウェブサイトの規制により,関連品を購入するユニットまたは個人は,有効な資格および資格条件を取得する必要があります.


オンラインメッセージ

連絡先情報

会社電話

+86-21-6420 0566

営業時間

月曜日から金曜日

携帯電話:

13816217984

メール:

info@qinsun-lab.com

QRコード