DescriptionA unique feature of TE 95 Precision Rotary Tribometer – Low Temperature Enabled is t
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
A unique feature of STD-TE 95 Precision Rotary Tribometer – Low Temperature Enabled is the use of a dual axis, in-line, torque and axial force transducer, allowing measurement of both axial load and friction torque on the rotating, upper specimen, as opposed to the more conventional methods associated with more standard rotary tribometers. Measuring the load and friction at the rotating specimen, instead of at the fixed lower specimen, means that the latter can be attached to bulky refrigerant pipes, without inducing unwanted tare forces.
Tests may be run using geometries specified in the following standards:
• ASTM G99 Wear Testing with a Pin-on-Disc Apparatus
• ASTM D3702 Standard Test Method for Wear Rate of Materials in Self-Lubricated Rubbing Contact Using a Thrust Washer Testing Machine
• ASTM D2266 Wear Preventive Characteristics of Lubricating Greases
• ASTM D4172 Wear Preventive Characteristics of Lubricating Fluid
• ASTM D5183 Determination of the Coefficient of Friction of Lubricants
Customised test assemblies and tooling can be accommodated, provided these work with axi-symmetric loading and produce a pure couple friction torque.
Rotational Speed: | 30 to 3.000 rpm |
Load Range: | 10 to 1.000 N |
Maximum Friction Torque: | 10 Nm |
Motor: | a.c. servo |
Motor Output: | 16 Nm @ 4.000 rpm continuous rated |
Drive Belt: | Poly-vee |
Interface: | Serial Link Interface Module |
Software: | COMPEND 2000 |
Controlled Parameters | Rotational Speed |
ふか | |
Temperature | |
テスト期間 | |
Measured Parameters | Rotational Speed |
Wear | |
Friction Force | |
Temperature | |
Number of Revolutions | |
テスト期間 | |
Sliding Speed | |
Friction Coefficient | |
Sliding Distance | |
Adapters and Tooling | |
TE 95/1 Cooled Test Assembly | |
Minimum Temperature: | -50°C |
Wear Sensor: | Linear Inductive Displacement Sensor |
Wear Resolution: | 0.2 microns |
Cooling System: | Laboratory Chiller |
TE 95/2 Heated Test Assembly | |
Maximum Temperature: | 150°C |
Wear Sensor: | Linear Inductive Displacement Sensor |
Wear Resolution: | 0.2 microns |
Heating System: | Band-heater |
TE 95/3 Thrust Washer/Three Pin on Disc Tooling | |
Thrust Washer: | According to ASTM D 3702 |
Pin Track Radius: | 10 to 35 mm |
Pin Size: | 8 mm diameter x 15 mm long |
Disc Diameter: | 75 mm maximum |
TE 95/4 Four Ball Wear Test Tooling | |
Services | |
Electricity: | 380/415V, three phase, 50/60 Hz, 7.5 kW |
Clean, dry air: | 4 cfm at 8 bar (120 psi) |
Installation | |
Floor-standing machine: | 900 mm x 600 mm deep x 2000 mm high, 250 kg |
Floor-standing cabinet: | 600 mm x 600 mm x 1800 mm high, 150 kg |
Packing Specifications: | 2.2 m3, GW 550 kg, NW 400 kg |